Cakewalk // Documentation // SONAR X2 // Changing the meters’ performance
Table of Contents Previous Next Index

MixingMetering ► Changing the meters’ performance

There are two major factors that determine the performance of meters in SONAR. One is audio latency which you can adjust, within the limits of your audio hardware drivers, in Edit > Preferences > Audio - Driver Settings . The second is the settings in Edit > Preferences > Customization - Audio Meters.
SONAR has configurable meter ballistics that allow you to adjust the rise and fall times of both the RMS and Peak Meters. Out of the box, SONAR ships with industry-standard settings that mimic meter ballistics for common hardware consoles.
To adjust the meter performance, go to Edit > Preferences > Customization - Audio Meters and follow these guidelines:
Table 164.  
Adjust the Refresh rate field. Valid values are from 25 to 250 milliseconds.
Change the decay rate (the amount of time the meter display stays at its peak)
Adjust the Decay Rate value. Valid values are from 1 to 150 milliseconds.
Increase or decrease the amount of time the meter displays a peak value
Adjust the Hold Time value. Valid values are from 0 to 5000 milliseconds.
Adjust the Rise or Fall settings for RMS or Peak. Valid Rise values are from 0 to 1000 milliseconds. Valid Fall values are from 0 to 2500 milliseconds.
list-image
Peak Hold – Decay Rate = 50 msec
list-image
Peak Hold – Hold Time = 750 msec

Copyright © 2024 Cakewalk, Inc. All rights reserved